Rooftop Solar Water Heating Array and Insulated Storage Tanks
Solar Thermal Energy Harvesting

Solar Water Heaters for Homes, Hotels & Commercial Facilities

Reliable ETC and FPC solar thermal solutions engineered to deliver continuous hot water while drastically reducing morning electricity bills across Telangana and Andhra Pradesh.

Deccan Solar Thermal Potential

Eliminating Morning Peak Electrical Spikes with Direct Sun Absorption

In residential apartments, multi-bedroom villas, commercial hotel suites, and student hostels across Telangana and Andhra Pradesh, water heating accounts for 20% to 35% of monthly winter and monsoon electricity tariffs. Conventional resistance-coil electric geysers pull 2,000 to 3,000 Watts per bathroom during morning peak utility tariff slabs.

By capturing solar infrared and ultraviolet thermal energy directly through high-absorbance evacuated glass tubes or copper flat-plate collectors, water temperatures easily reach 60°C to 80°C without consuming a single unit of grid electricity.

Engineered with high-density pressurized polyurethane (PUF) thermal insulation jackets, Dr.MAK solar water heating systems preserve stored water temperature overnight, ensuring boiling-hot baths and kitchen dishwashing before dawn breaks.

Up to 80°C
Thermal Output
Naturally achieved with selective multi-layer absorption coatings
72 Hours
Heat Retention
50mm high-density injected PUF thermal insulation tanks
~70% Cut
Geyser Bill Reduction
Immediate elimination of high-amperage morning geyser loads
Rooftop Commercial Solar Thermal Water Heating Installation High-Density Insulated Storage Arrays

Multi-bank solar thermal arrays fitted with food-grade SUS-304 stainless steel storage tanks and sacrificial magnesium scaling anodes.

Engineering & Operational Principles

How Solar Water Heating Works

A solar water heater uses thermal collectors to absorb sunlight and transfer the captured heat to water. The heated water is stored in an insulated tank until it is needed.

Unlike photovoltaic solar panels, which generate electricity, solar thermal collectors primarily capture heat.

The main components generally include solar collectors, an insulated storage tank, connecting pipes, mounting arrangements, and suitable controls. Some systems use natural circulation, while others use pumps or other circulation arrangements depending on their design. An auxiliary heater may be required during extended cloudy periods or when demand exceeds the available hot-water supply.

01. Direct Solar Absorption

Solar thermal collectors absorb sunlight via selective multi-layer magnetron sputtering, converting radiant ultraviolet and infrared light directly into concentrated heat.

• Absorption Efficiency > 93%
• Low Emissivity (< 7%)

02. Thermosiphon Circulation

As water inside the tubes heats, its density decreases. The lighter warm water naturally rises upward into the storage tank while colder, denser water descends into the collector bottom without mechanical pumps.

• Natural Gravity Driven
• Zero Electrical Pumping Energy

03. PUF Insulated Storage

Hot water is preserved inside an inner vessel lined with food-grade stainless steel or vitreous enamel, wrapped in a 50mm thick high-pressure injected polyurethane foam (PUF) insulation jacket.

• SUS-304L Food-Grade Liner
• Minimal Heat Loss (< 4°C/Night)

04. Smart Auxiliary Booster

An automated thermostatically controlled electrical immersion backup element turns on only when prolonged monsoon rains or sudden peak guest demand exceeds the solar thermal reserve.

• 2 kW - 3 kW Auxiliary Backup
• Automatic Thermostat Cut-Off
Collector Technologies

Types of Solar Water Heaters

Choosing between Flat Plate Collectors (FPC) and Evacuated Tube Collectors (ETC)

The suitable collector type depends on the application, local conditions, water quality, installation space, and equipment specifications. Both technologies capture solar radiation efficiently, but their operating physics, pressure endurance, and maintenance requirements serve distinct building plumbing architectures.

Flat Plate Collector Solar Water Heating Installation Pressurized & Commercial Grade
Copper Riser & Toughened Glass

Flat Plate Collector Systems

These systems use an absorber plate inside an insulated collector casing. They are available for domestic and larger hot-water applications.

Featuring an array of ultrasonic-welded high-purity copper riser pipes bonded to a copper absorber sheet coated with black chrome or selective titanium oxide, FPC units are enclosed inside an extruded marine-grade aluminum frame and covered with low-iron tempered shatterproof glass.

Engineering Characteristics:
• Operates under high hydro-pneumatic pressure (up to 5 Bar)
• Shatterproof 4mm tempered solar glass
• Copper-to-copper long lifecycle durability
• Ideal for treated municipal soft water
Best Application: Pressurized Villa Plumbing & Luxury Hotels
Evacuated Tube Collector Solar Water Heater on Rooftop High Thermal Efficiency
Borosilicate Vacuum Glass Tubes

Evacuated Tube Collector Systems

These use specially designed glass tubes to reduce heat loss and collect solar heat.

Constructed from two concentric high-strength borosilicate 3.3 glass tubes fused together, the outer tube is transparent while the inner tube is coated with a graded selective multi-layer (Al-N/Al) absorber. The air between the two concentric tubes is completely evacuated into a permanent vacuum, eliminating convective and conductive heat dissipation to the outside atmosphere.

Engineering Characteristics:
• Outstanding performance in cold mornings & diffuse winter light
• Excellent scaling resistance with hard borewell water
• Individual tube replacement without tank drainage
• Highly pocket-friendly capital investment
Best Application: Hard Water Zones, Homes, Hostels & Hospitals
Sector Specific Engineering

Engineered For Residential, Commercial & Institutional Facilities

From 100 LPD individual domestic villas to 10,000+ LPD centralized hospital manifolds
Residential Solar Water Heating on Rooftop Residential Installations

Residential Solar Water Heating

Residential systems can be planned according to the number of occupants, daily hot-water consumption, available roof space, and desired storage capacity.

An appropriately sized system can help reduce the conventional energy used for bathing and other domestic hot-water requirements.

Correct installation of the collectors, storage tank, pipes, and insulation is important for performance and convenient operation.

Domestic Residential Features:
• Compact 100 to 500 LPD capacities
• Anti-scaling sacrificial magnesium anodes
• Multi-layer thermal pipe insulation
• Overheat air vent & vacuum breaker valves
Typical System Sizing: 100 LPD to 500 LPD Units
Commercial and Institutional Solar Water Heating Manifolds Hotels, Hostels & Hospitals

Commercial and Institutional Applications

Hotels, hostels, hospitals, educational institutions, restaurants, and residential complexes may have significant daily hot-water requirements.

Commercial solar water heating systems need to account for peak demand, storage capacity, plumbing arrangements, backup heating, and operating schedules.

Dr.MAK aims to help customers understand these considerations before selecting a system for their facility.

Commercial & Campus Capabilities:
• Multi-collector centralized header banks
• Motorized re-circulation ring mains
• Industrial heat exchangers & calorifiers
• Automated multi-stage immersion boosters
Typical System Sizing: 1,000 LPD to 15,000+ LPD Arrays
Value Engineering & Thermal Prudence

Customized and Pocket-Friendly Solutions

Every property has different hot-water requirements. Choosing the appropriate collector configuration and storage capacity helps align the installation with actual usage.

Our focus is on helping customers understand suitable system options and evaluate the practical implications of equipment selection, installation, and maintenance.

Water quality is also important because mineral deposits may affect some systems. Periodic inspection of collectors, pipes, valves, insulation, and storage arrangements can help identify maintenance needs.

Water Quality & Hardness

Evaluating Total Dissolved Solids (TDS) and mineral content prevents limescale choke-up in copper headers, ensuring appropriate selection of ETC vacuum tubes or sacrificial anodes.

Thermal Pipe Insulation

We sheath all rooftop plumbing lines in closed-cell elastomeric nitrile rubber or glass-wool insulation with UV-protective aluminum wrapping to eliminate transit heat dissipation.

Accurately Sized Storage

Preventing undersizing (cold morning disappointment) and oversizing (unnecessary capital expenditure) by calculating exact bathroom shower flow rates and kitchen tap runs.

How it works

Hot water with no power bill

Collector absorbs sunlight

Evacuated tubes or a flat plate collector soak up heat from the sun.

Heated water rises

Warm water is lighter, so it rises into the tank on its own while cooler water takes its place.

Insulated tank stores it

The insulated stainless steel tank keeps water hot through the night for early morning use.

Hot water at your taps

Hot water flows to bathrooms and kitchens, and the tank refills with cold water to heat again.

Often planned together

Related services

Water Heating Advisory

Explore a customized solar water heating system designed around your daily hot-water needs and available installation space.

Connect directly with our thermal energy engineers in Kapra, Secunderabad. We calculate daily Litres Per Day (LPD) requirements, inspect plumbing pressures, assess water hardness, and provide itemized turnkey proposals.

Direct Operations Desk: +91 6304 74 66 27
Official Emails: info@drmakserv.com / sarvinsgroup@gmail.com
Flat No : 101, Sony Heights Block - A, Vinayaka Nagar, Phase II, Kapra, Secunderabad

Request a Water Heating Assessment

Share your property details and occupant numbers; our engineers will contact you promptly.